Data Center Cooling Reimagined: Turning Waste Heat into Thermal Efficiency
MetisPowerChill™: An Integrated Data Center Cooling
The MetisPowerChill™ (MPC) architecture resolves the inefficiency of siloed systems by treating power and cooling as a unified ecosystem. Instead of venting valuable thermal energy into the atmosphere, the system captures exhaust heat and converts it directly into chilled water.
Operational Workflow:
- Generation: Powered by our core data center power solutions, MPG Series extra low-emission gas turbines generate reliable, continuous electricity for the IT load.
- Capture: The Integrated Exhaust System captures thermal energy that would typically be wasted.
- Conversion: The MPE Exhaust-Driven Chiller utilizes this thermal flow to drive the refrigeration cycle, replacing the heavy electrical load of mechanical compressors.
- Cooling: High-capacity chilled water is delivered to the data hall for mission-critical data center cooling, effectively decoupling thermal management costs from grid electricity rates.

Why Thermal Cooling Superiority Matters
Resilience
Engineered for thermal extremes, the system maintains a stable 1.17 PUE even at 105°F (40°C), eliminating the cooling capacity loss common in standard air-cooled chillers during heatwaves.
Autonomy
Driven by recaptured exhaust heat rather than grid electricity, the cooling loop is immune to utility price spikes, peak demand charges, and grid instability.
Efficiency
Utilizing the fuel source twice, once for power, once for cooling, raises overall system efficiency to ~54%, drastically lowering the facility’s carbon intensity per rack.

See the Difference: Power vs. Thermal
Drag the slider to reveal the structural advantage of the MetisPowerChill™ system. Witness how shifting from electrical cooling (Left) to thermal recovery data center cooling (Right) streamlines the facility design and fundamentally alters the operational cost equation.
8,760,000
kWh / Year Savings

Quantify Efficiency Advantage - Integrated Data Center Cooling
Every megawatt of power generated creates a thermal opportunity. Instead of venting exhaust heat as waste, the MetisPowerChill™ system captures it to drive mission-critical cooling. Enter the facility’s target IT load below to project the recoverable cooling capacity and the massive grid energy savings achievable through an integrated data center cooling.
Energy as a Service
Long Term Agreement to deliver the required power to your data center.
Build your Power Plant
We design, build, and operate the plant that provides power to your data center.